BioClean Nitrile RABS/Isolator Sleeve/Glove

BioClean Nitrile RABS/Isolator Sleeve/Glove

When it comes to maintaining the highest levels of sterility and safety in controlled environments, precision matters.

The BioClean Nitrile RABS/Isolator Sleeve/Glove is designed to provide the ultimate protection for operators working in sterile and high-contamination-sensitive settings such as pharmaceutical production, biotechnology, and semiconductor manufacturing.

Product Overview

Clean & sterile nitrile RABS / isolator sleeve / glove

The GSG10NIT85 is a sterile, high-performance arm cuff/glove system specifically engineered for use in Restricted Access Barrier Systems (RABS) and isolators. Made from a combination of nitrile and neoprene, it ensures a perfect balance of durability, comfort, and protection. With a BioClean BPZS glove attached to a nitrile arm cuff, this system offers an airtight seal, keeping contamination at bay while providing excellent dexterity and flexibility.

Key Features & Benefits

  • Material Integrity: The arm cuff is constructed from nitrile and neoprene, offering a sterile, material-pure solution that minimizes the risk of contamination in sensitive environments.
  • Cytostatic Drug Handling: Compliant with ASTM D6978-05 standards, this arm cuff system is specifically tested and certified for handling cytostatic drugs, ensuring the safety of both operators and the working environment when handling hazardous substances.
  • Sterile and Clean: The cuff’s outer surface is designed to be extremely clean, providing maximum protection for sensitive products. The system is fully inspected and airtight tested to meet the highest standards for sterility and performance.
  • Versatile Fit: Compatible with port sizes ranging from 254 mm to 304 mm, the cuff ensures a secure and airtight fit for a wide variety of isolator and RABS systems.
  • Ready-to-Use System: The product comes as a complete unit, including the arm cuff, PCP glove (size 8.5), and sealing ring, making it easy to use right out of the package.
  • Dual-Glove Solution: The system comes with a size 8.5 PCP glove that provides superior tactile sensitivity while working within isolators or RABS, offering protection without sacrificing dexterity.

Applications

RABS and Isolator Gloves

The RABS/Isolator Arm Cuff GSG10NIT85 is ideal for use in the following industries and applications:

  • Pharmaceutical Production: Ensures sterility when handling active ingredients, formulations, and other sensitive materials during manufacturing.
  • Biotechnology & Research: Perfect for labs involved in the development and production of biological and medical products, requiring a high degree of contamination control.
  • Semiconductor Manufacturing: Helps maintain the integrity of sensitive electronics by preventing exposure to contaminants and static.
  • Sterilization Departments & Cleanrooms: Essential for workers in cleanroom environments where air quality and sterility are critical for product safety.

Packaging

  • Individual Packaging: Each arm cuff system is packed in a triple-bag system, which includes a nitrile arm cuff, size 8.5 glove, and sealing ring. This packaging ensures that each unit is ready to use without contamination risks.
  • Bulk Packaging: Each system is packed with 10 units per Correx box, which contains 20 systems per outer box, making bulk storage and inventory management easy and efficient.

The RABS/Isolator Arm Cuff GSG10NIT85 is the ideal solution for high-risk industries that require reliable protection and sterility. Its design combines comfort, durability, and safety, providing operators with the confidence they need to perform their tasks while minimizing contamination risks. Whether you’re working in pharmaceutical manufacturing, laboratory environments, or semiconductor production, this arm cuff system ensures that you maintain a sterile, controlled environment, enhancing both safety and operational efficiency.

How to Properly Wear and Remove Sterile Gloves

How to Properly Wear and Remove Sterile Gloves : A Comprehensive Guide

In medical, laboratory, and other environments requiring strict sterility, the correct procedure for wearing and removing sterile gloves is crucial.

Whether you are a doctor, nurse, or lab technician, mastering this skill is essential to protect yourself and prevent cross-contamination.

Below is a detailed guide on how to wear and remove sterile gloves and important precautions to follow.

PUREZERO HG3 Sterile Nitrile Gloves

The PUREZERO HG3 sterile nitrile gloves are designed for critical cleanroom environments, such as pharmaceutical manufacturing and sterile compounding, offering superior protection.


Preparation Before Wearing Sterile Gloves

  1. Clean Your Hands
    • Thoroughly wash your hands with soap and running water. Pay special attention to areas like between the fingers, under the nails, and around the wrists.
    • Dry your hands completely using a clean paper towel or a hand dryer.
  2. Choose the Right Gloves
    • Select gloves that fit your hands comfortably. Gloves that are too small may tear, while gloves that are too large may hinder your grip.
    • Ensure the gloves are not expired and the packaging is intact.
  3. Prepare a Sterile Environment
    • Ensure the workspace is clean and disinfected. Surfaces that might come in contact with the gloves should be sterilized to prevent contamination.

Steps to Wear Sterile Gloves Properly

  1. Open the Package
    • Carefully tear open the glove package without touching the gloves inside. Place the gloves on a sterile surface.
  2. Put on the First Glove
    • Using your ungloved hand, hold the edge of the first glove and gently slide your hand inside. Ensure the glove’s interior remains uncontaminated.
  3. Put on the Second Glove
    • Using your gloved hand, hold the edge of the second glove. Avoid touching the outside surface of the glove and gently insert your other hand.
  4. Adjust the Gloves
    • Check that the gloves fit snugly and cover your wrists. Adjust carefully to ensure proper fit without compromising sterility.

Precautions While Wearing Sterile Gloves

Disposable Consumables

From gloves and pipette tips to sterile filters, we offer a wide range of products to support your laboratory needs.

  1. Avoid Non-Sterile Surfaces
    • Once the gloves are on, do not touch anything outside the sterile field.
  2. Maintain Proper Posture
    • Keep your hands in a position that reduces strain on the gloves, such as at chest level.
  3. Regular Checks
    • Inspect your gloves during use for tears or damage. Replace immediately if compromised.

How to Safely Remove Sterile Gloves

  1. Start With the First Glove
    • Pinch the outside of the first glove near the wrist without touching your skin. Pull the glove inside out as you remove it.
  2. Remove the Second Glove
    • Hold the first glove in your gloved hand. Slide your bare fingers inside the second glove at the wrist and peel it off inside out, enveloping the first glove.
  3. Dispose of Used Gloves
    • Place the gloves in a designated medical waste container. Never dispose of them in regular trash bins.
  4. Clean Your Hands Again
    • Wash your hands thoroughly with soap and water after removing the gloves to ensure no contaminants remain.

Key Points to Remember

  • Always work in a clean, sterile area to maintain glove sterility.
  • Replace gloves immediately if they become torn or contaminated.
  • Never reuse disposable sterile gloves.
  • Practice the procedure regularly to ensure proficiency.

latex gloves

By following these steps, you can maintain a sterile environment and uphold the highest standards of hygiene and safety in your work. Proper use of sterile gloves protects not only you but also those you serve, ensuring a safer and more effective workflow.